• Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Every member from our high efficiency sales team values customers' needs and business communication for Pipettor, Glassware, Portable Water Velocity Meter, Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software advancement are our distinguishing feature.
Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng Detail:

Water-carrying caliber Ф200 ± 0.6mm
Measuring range ≤4mm / min (precipitation intensity)
Resolution 0.2mm (6.28ml)
Accuracy ± 4% (indoor static test, rain intensity is 2mm / min)
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Output form Current 4 ~ 20mA
Switching signal: On-off of reed switch
Voltage: 0~2.5V 
Voltage: 0~5V    
Voltage 1 ~ 5V
Other
Instrument line length Standard: 5 meters
Other
Working temperature 0 ~ 50 ℃
Storage temperature -10 ℃ ~ 50 ℃

1. If equipped with a weather station produced by the company, directly connect the sensor to the corresponding interface on the weather station using a sensor line;

2. If the sensor is purchased separately, as the sensor outputs a set of switching signals, the cable connector does not matter positive and negative. Connect the sensor to the circuit as shown in the figure.

lf-0004-rain

If the sensor outputs other signals, the corresponding line sequence and function of the conventional sensor are as follows:

Line color Output signal
Voltage Current communication
Red Power + Power + Power +
Black(green) Power ground Power ground Power ground
Yellow Voltage signal Current signal A+/TX
Blue     B-/RX

lf-0004-rain1

Structure Dimensions 

lf-0004-rain2

Transmitter size  

1. the serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 01 XX XX
Note: as shown below:

Code Function definition Note
Adress Station number (address)  
03 Function code  
00  00 Initial address  
00  01 Read points  
XX XX CRC Check code,front low later high  

Returns: Adress 03 02 XX XX XX XX YY YY
Note

Code Function definition Note
Adress Station number (address)  
03 Function code  
02 Read unit byte  
XX  XX Data (high before, low after) Hex
XX  XX CRCCheck code  

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit。
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

RS485 circuit

1. The installation position of the sensor can be selected on the ground, self-made big tube, iron pillar flange or on the roof of the house according to actual requirements.
2. Adjust the three leveling screws on the chassis to make the level bubble indication level (the bubble stays in the center of the circle), and then slowly tighten the three M8 × 80 fixing expansion screws; if the level bubble changes, you need to readjust.
3. Assemble and fix the sensor as shown in the figure above.
4. After fixing, open the rain bucket and cut off the nylon cable ties on the funnel, slowly inject fresh water into the rain sensor, and observe the turning process of the bucket to check whether the data is received on the acquisition instrument. Finally, quantitative water (60-70mm) is injected. If the data displayed by the acquisition instrument is consistent with the amount of injected water, the instrument is normal, otherwise it must be repaired and adjusted.
5. Avoid disassembling the sensor during installation.

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect line with power on. Only check the wiring and make sure the power is on.
3. The sensor cable length will affect the output signal of the product. Do not arbitrarily place the components or wires that have been soldered when the product leaves the factory. If there is a need for change, please contact the manufacturer.
4. The sensor should be inspected regularly to remove dust, mud, sand, leaves and insects, so as not to block the water flow channel of the upper tube (funnel). The cylindrical filter can be removed and washed with water.
5. There is dirt on the inner wall of the dump bucket, which can be washed with water or alcohol or detergent aqueous solution. It is strictly forbidden to wipe with fingers or other objects, so as not to get oily or scratch the inner wall of the dump bucket.
6. During freezing in winter, the instrument should be stopped and can be taken back to the room.
7. Please save the verification certificate and the certificate of conformity, and return it with the product when repairing.

1. The display meter has no indication. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. The displayed value of the display is obviously inconsistent with the actual situation. Please empty the water bucket and refill the bucket with a certain amount of water (60-70mm), and clean the inside wall of the bucket.
3. If it is not the above reasons, please contact the manufacturer.

No Power supply Output Signal Instructions
LF-0004     Rain sensor
  5V-    
12V-    
24V-    
YV-    
  M Switch signal output
V 0-2.5V
V 0-5V
W2 RS485
A1 4-20mA
X Other
E.g.: LF-0014-5V-M: Rain sensor. 5V power supply, switch signal output

Product detail pictures:

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng detail pictures


Related Product Guide:

Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Special Design for Mass Air Flow Sensor Temperature - Rain sensor stainless steel outdoor hydrological station – Huacheng , The product will supply to all over the world, such as: Norwegian, Ethiopia, Congo, Business philosophy: Take the customer as the Center, take the quality as the life, integrity, responsibility, focus, innovation.We will provide professional, quality in return for the trust of customers, with most major global suppliers,all of our employees will work together and move forward together.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Jo from Costa rica - 2018.09.21 11:44
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Jean from Brasilia - 2017.11.11 11:41
    Write your message here and send it to us

    Related products

    • OEM/ODM China Total Element Weather Station - LF-0012 handheld weather station – Huacheng

      OEM/ODM China Total Element Weather Station - ...

      LF-0012 handheld weather station is a portable meteorological observation instrument that is convenient to carry, easy to operate, and integrates many meteorological elements. The system uses precision sensors and smart chips to accurately measure the five meteorological elements of wind speed, wind direction, atmospheric pressure, temperature, and humidity. The built-in large-capacity FLASH memory chip can store meteorological data for at least one year: universal USB communication interface...

    • Low price for Weather Sensor - LF-0010 TBQ Total Radiation Sensor – Huacheng

      Low price for Weather Sensor - LF-0010 TBQ Tot...

      This sensor is used to measure the spectral range of 0.3-3μm, solar radiation, can also be used to measure the incident solar radiation to the slant of the reflected radiation can be measured, such as the induction downwardly facing, light shielding ring measurable scattered radiation. Therefore, it can be widely applied to the use of solar energy, meteorology, agriculture, building materials, aging and atmospheric pollution and other departments to do the measurement of solar radiation energ...

    • OEM/ODM Supplier Rain Gauge Outdoor - Microcomputer automatic calorimeter – Huacheng

      OEM/ODM Supplier Rain Gauge Outdoor - Microcom...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Best quality Test-Tube Rack - Microcomputer automatic calorimeter – Huacheng

      Best quality Test-Tube Rack - Microcomputer au...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Chinese wholesale Laboratory Clamps - Microcomputer automatic calorimeter – Huacheng

      Chinese wholesale Laboratory Clamps - Microcom...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • High definition Rain Gauge And Thermometer - Microcomputer automatic calorimeter – Huacheng

      High definition Rain Gauge And Thermometer - M...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...