It adheres for the tenet "Honest, industrious, enterprising, innovative" to develop new products and solutions continuously. It regards shoppers, success as its individual success. Let us produce prosperous future hand in hand for Glass Dropper, Cod Analysis, 50 Holes Test Tube Rack, It can be our wonderful honor to meet your requires.We sincerely hope we can cooperate along with you inside the around long term.
Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng Detail:

Measurement range -50~100℃
-20~50℃
Accuracy ±0.5℃
Power supply DC 2.5V 
DC 5V 
DC 12V 
DC 24V 
Other
Out-put Current: 4~20mA 
Voltage: 0~2.5V 
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Line length Standard: 10 meters
Other  
Load capacity Current output impedance≤300Ω
Voltage output impedance≥1KΩ
Operating environment Temperature: -50℃~80℃
Humidity: ≤100%RH    
Produce weight Probe 145 g, with collector 550 g
Power dissipation 0.5 mW

Voltage type (0~5V):
T=V / 5 × 70 -20
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -20 ~ 50 ℃)
T=V / 5 × 150 -50
(T is the measured temperature value (℃), V is the output voltage (V), this formula corresponds to the measurement range -50 ~ 100 ℃)
Current type (4~20mA)
T=(I-4)/ 16 × 70 -20
(T is the measurement temperature value (℃), I is the output current (mA), this type corresponds to the measurement range -20 ~ 50 ℃)
T=(I-4)/ 16 × 150 -50
(T is the measured temperature value (℃), I is the output current (mA), this formula corresponds to the measurement range -50 ~ 100 ℃)
Note: The calculation formulas corresponding to different signal outputs and different measurement ranges need to be recalculated!

1. If equipped with a weather station produced by our company, directly connect the sensor to the corresponding interface on the weather station using the sensor cable.
2. If the transmitter is purchased separately, the matching cable sequence of the transmitter is:

Line color

Output signal

Voltage type

Current type

Communication type

Red

Power+

Power+

Power+

Black (green)

Power ground

Power ground

Power ground

Yellow

Voltage signal

Current signal

A+/TX

Blue

 

 

B-/RX

3. Transmitter voltage and current output wiring:

LF-0020 water temperature sensor5

Wiring for voltage output mode 

LF-0020 water temperature sensor6

Wiring for current output mode

LF-0020 water temperature sensor7

(Water temperature sensor)

LF-0020 water temperature sensor8

(Water temperature sensor)

1. The serial format
Data bits 8 bits
Stop bit 1 or 2
Check Digit None
Baud rate 9600 Communication interval is at least 1000ms
2. Communication format
[1] Write device address
Send: 00 10 Adress CRC (5 bytes)
Returns: 00 10 CRC (4 bytes)
Note: 1. The address bit of the read and write address command must be 00.
2. Adress is 1 byte and the range is 0-255.
Example: Send 00 10 01 BD C0
Returns 00 10 00 7C
[2] Read device address
Send: 00 20 CRC (4 bytes)
Returns: 00 20 Adress CRC (5 bytes)
Explanation: Adress is 1 byte, the range is 0-255
For example: Send 00 20 00 68
Returns 00 20 01 A9 C0
[3] Read real-time data
Send: Adress 03 00 00 00 02 XX XX
Note: as shown below:

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

00  00

Initial address

 

00  01

Read points

 

XX XX

CRC Check code,front low later high

 

Returns: Adress 03 02 XX XX XX XX

Code

Function definition

Note

Adress

Station number (address)

 

03

Function code

 

02

Read unit byte

 

XX  XX

Soil temperature data (high before, low after)

Hex

XX  XX

Soil humidity data (high before, low after)

 

To calculate the CRC code:
1. The preset 16-bit register is FFFF in hexadecimal (that is, all are 1). Call this register the CRC register.
2. XOR the first 8-bit data with the lower bit of the 16-bit CRC register and put the result in the CRC register.
3. Shift the contents of the register to the right by one bit (toward the low bit), fill the highest bit with 0, and check the lowest bit.
4. If the least significant bit is 0: repeat step 3 (shift again), if the least significant bit is 1: the CRC register is XORed with the polynomial A001 (1010 0000 0000 0001).
5. Repeat steps 3 and 4 until 8 times to the right, so that the entire 8-bit data has been processed.
6. Repeat steps 2 to 5 for the next 8-bit data processing.
7. The CRC register finally obtained is the CRC code.
8. When the CRC result is put into the information frame, the high and low bits are exchanged, and the low bit is first.

LF-0020 water temperature sensor9

Connect the sensor according to the instructions in the wiring method, and then insert the sensor probe into the soil to measure the temperature, and supply power to the collector and the sensor to obtain the water temperature at the measurement point.  

1. Please check whether the packaging is intact and check whether the product model is consistent with the selection.
2. Do not connect with power on, and then power on after checking the wiring.
3. Do not arbitrarily change the components or wires that have been soldered when the product leaves the factory.
4. The sensor is a precision device. Please do not disassemble it by yourself or touch the surface of the sensor with sharp objects or corrosive liquids in order to avoid damaging the product.
5. Please keep the verification certificate and certificate of conformity, and return it with the product when repairing.

1. When the output is detected, the display indicates that the value is 0 or is out of range. Check whether there is obstruction from foreign objects. The collector may not be able to obtain the information correctly due to wiring problems. Please check whether the wiring is correct and firm.
2. If it is not the above reasons, please contact the manufacturer.

Number

Power supply mode

Output signal

Explain

LF-0020

 

 

Water temperature sensor

 

5V-

 

5V powered

12V-

 

12V powered

24V-

 

24V powered

YV-

 

Other powered

 

0

No change

V

0-5V

V1

1-5V

V2

0-2.5V

A1

4-20mA

A2

0-20mA

W1

RS232

W2

RS485

TL

TTL

M

Pulse

X

Other

For example: LF-0020-24V-A1: water temperature sensor (transmitter)

24V power supply, 4-20mA output


Product detail pictures:

Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng detail pictures

Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng detail pictures


Related Product Guide:

We provide good power in high-quality and progress,merchandising,revenue and internet marketing and operation for Special Design for Mass Air Flow Sensor Temperature - LF-0020 water temperature sensor – Huacheng , The product will supply to all over the world, such as: Ukraine, Bangalore, Slovenia, We are adhering to the philosophy of "attracting customers with the best products and excellent service". We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Martina from Greece - 2018.06.12 16:22
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Riva from Kyrgyzstan - 2017.12.02 14:11
    Write your message here and send it to us

    Related products

    • Cheap price Portable Gas Concentration Detector - Single Gas Detector User’s manual – Huacheng

      Cheap price Portable Gas Concentration Detector...

      For security reasons, the device only by suitably qualified personnel operation and maintenance. Prior to the operation or maintenance, please read and fully manage all solutions to these instructions. Including operations, maintenance of equipment and process methods. And a very important safety precautions. Read the following Cautions before using the detector. Table 1 Cautions Cautions 1. Warning: Unauthorized replacement of replacement parts in order to avoid the impact of the instru...

    • Competitive Price for Outdoor Rain Sensor - PH Sensor – Huacheng

      Competitive Price for Outdoor Rain Sensor - PH...

      The new-generation PHTRSJ soil pH sensor solves the shortcomings of traditional soil pH that requires professional display instruments, tedious calibration, difficult integration, high power consumption, high price, and difficult to carry. ● New soil pH sensor, realizing online real-time monitoring of soil pH. ● It adopts the most advanced solid dielectric and large-area polytetrafluoroethylene liquid junction, which is not easy to block and maintenance-free. ● High integration, small size, l...

    • Discount wholesale Micro Analytical Balance - Laboratory products support custom laboratory various instruments and equipment – Huacheng

      Discount wholesale Micro Analytical Balance - ...

    • Top Quality Temperature Pressure And Humidity Sensor - Rain sensor stainless steel outdoor hydrological station – Huacheng

      Top Quality Temperature Pressure And Humidity S...

      Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other Instrument line length Standard: 5 meters Other Working temperature 0 ~ 50 ℃ Storage temperature -10 ℃ ~ ...

    • OEM/ODM China Total Element Weather Station - LF-0012 handheld weather station – Huacheng

      OEM/ODM China Total Element Weather Station - ...

      LF-0012 handheld weather station is a portable meteorological observation instrument that is convenient to carry, easy to operate, and integrates many meteorological elements. The system uses precision sensors and smart chips to accurately measure the five meteorological elements of wind speed, wind direction, atmospheric pressure, temperature, and humidity. The built-in large-capacity FLASH memory chip can store meteorological data for at least one year: universal USB communication interface...

    • Best quality Noise Tester - Microcomputer automatic calorimeter – Huacheng

      Best quality Noise Tester - Microcomputer auto...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...