• Short Lead Time for Large Pipette - Microcomputer automatic calorimeter – Huacheng

Short Lead Time for Large Pipette - Microcomputer automatic calorimeter – Huacheng

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Gaining purchaser gratification is our firm's intention eternally. We will make wonderful endeavours to build new and top-quality merchandise, satisfy your exclusive needs and provide you with pre-sale, on-sale and after-sale products and services for Handheld Anemometer With Wind Direction, Bod Cod Tss Analyser, Folding Hopper, We will keep working hard and as we try our best to supply the best quality products, most competitive price and excellent service to every customer. Your satisfaction, our glory!!!
Short Lead Time for Large Pipette - Microcomputer automatic calorimeter – Huacheng Detail:

Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials.

In line with GB/T213-2008 “Coal thermal determination Method”

GB/T384 “Determination of calorific value of petroleum products”

JC/T1005-2006 “Cement black raw material calorific value determination method”

ASTM D5865-2010 “Test Method for Total Calorific Value of Coal and Coking Coal”

GB/T30727-2014 “Solid biomass fuel calorific value determination method”

ISO 1928-2009 “Solid mineral Fuels – Determination of Total Value and Calculation of Net Calorific Value by bomb Calorimeter” requirements.

● It is mainly composed of constant temperature calorimetry system and single-chip microcomputer control system. It is a highly automatic heat measuring instrument controlled by single-chip microcomputer system and capable of data processing.

● The instrument is mainly used for coal, petroleum, chemical, food, wood and other combustible material calorific value measurement, in the measurement of the barrel calorific value at the same time conversion of the corresponding high calorific value and low calorific value.

Adopt American technology touch type LCD screen, integral installation method, ensure the firmness of touch screen.

Infrared technology, CRT display material to make the touch screen more durable. Multi-layer composite film cover, ensure color distortion, reflection and clarity to achieve the best state, sensitive induction, high positioning accuracy, effective infested area up to 90% wear resistance, life can be up to 10 years.

Chinese characters display, without external computer, can be operated directly. Can store more than 1000 data, display heating curve.

Adopt advanced single chip microcomputer system, the operation is fully automatic, the manual need to do is weighing, loading and oxygen, the instrument automatically complete quantitative water injection, automatic mixing, ignition, output printing results, drainage and other work.

Reasonable structure, reliable performance, low failure rate. The results are accurate and the unique cooling correction system ensures the stability of the instrument performance for a long time.

● Controlled by microcomputer, can provide reports of coal quality, man-machine interaction, namely learning. Automatic water injection, drainage, no need to adjust the water temperature, just install the oxygen bomb into the barrel, the instrument will automatically complete all the testing work.

● Accurate structure, unique cooling correction system, to ensure long-term stability of instrument performance. Electronic refrigeration process, completely not affected by environmental temperature changes, to ensure that the temperature difference between the inside and outside of the instrument meets the requirements of the national standard. Can work continuously for a long time.

● Fast test speed, test period ≤8min(rapid method) ≤15min, repeatability and reproducibility of calorific value test in line with GB/T384 “Determination of calorific value of Petroleum Products” standard, GB/T213-2008 “Coal calorific value determination Method” requirements.

The product provides excellent performance and reliability even in harsh environments.

● High degree of automation, automatic use of built-in fixed container bucket water, automatic control of the temperature difference between the inside and outside of the instrument bucket, automatic completion of the whole process of the test.

Rich data processing functions, users can easily query historical test data, data of the day, parallel sample data, etc.
Three, technical parameters:

Heat capacity about 10500 J/K
Temperature range 0~60 ℃
Oxygen bomb capacity 300ml
Response time < 4 S
Oxygen pressure 2.8~3.2 MPa
Resolution 0.0001 ℃
Pressure performance water pressure 20MPa
Linearity <0.08% within the range of temperature rise every 5℃
Weight 25 Kg
Temperature measurement error accuracy ±0.003℃ for every 5℃ temperature rise range
Dimensions 660mm×500mm×500mm
Supply voltage AC220V±10%
Humidity 80% or less
Power 30 w
Ignition voltage AC24V
Ignition time 5S

Product detail pictures:

Short Lead Time for Large Pipette - Microcomputer automatic calorimeter – Huacheng detail pictures


Related Product Guide:

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for Short Lead Time for Large Pipette - Microcomputer automatic calorimeter – Huacheng , The product will supply to all over the world, such as: Washington, Marseille, Islamabad, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective products and meticulous after-sales service. We firmly believe that: we are outstanding as we are specialized.
  • Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Eden from Mauritius - 2017.04.08 14:55
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Catherine from Mexico - 2017.06.16 18:23
    Write your message here and send it to us

    Related products

    • Manufacturer for O3 Gas Alarm - Compound Portable Gas Detector Operating Instruction – Huacheng

      Manufacturer for O3 Gas Alarm - Compound Porta...

      The composite portable gas detector adopts 2.8-inch TFT color screen display, which can detect up to 4 kinds of gases at the same time. It supports the detection of temperature and humidity. The operation interface is beautiful and elegant; it supports display in both Chinese and English. When the concentration exceeds the limit, the instrument will send out sound, light and vibration alarm. With real-time data storage function, and USB communication interface, can connect with the computer t...

    • Factory Supply Carbon Monoxide Wireless Gas Detector - Single-point Wall-mounted Gas Alarm Instruction Manual (Chlorine) – Huacheng

      Factory Supply Carbon Monoxide Wireless Gas Det...

      ● Sensor: catalytic combustion ● Responding time: ≤40s (conventional type) ● Work pattern: continuous operation, high and low alarm point(could be set) ● Analog interface: 4-20mA signal output[option] ● Digital interface: RS485-bus interface [option] ● Display mode: Graphic LCD ● Alarming mode: Audible alarm — above 90dB; Light alarm — High intensity strobes ● Output control: relay output with two way alarming control ● Additional function: time display, calendar display ● Storage...

    • Well-designed Room Air Temperature Sensor - LF-0020 water temperature sensor – Huacheng

      Well-designed Room Air Temperature Sensor - LF...

      Measurement range -50~100℃ -20~50℃ Accuracy ±0.5℃ Power supply DC 2.5V  DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Line length Standard: 10 meters Other   Load capacity Current output impedance≤300Ω Voltage output impedance≥1KΩ Operating environment Temperature: -50℃~80℃ Humidity: ≤100%RH     Produce weight Probe 145 g, with collector 550 g P...

    • Hot New Products Air Temperature And Humidity Sensor - Meteorological anemometer wind speed sensor – Huacheng

      Hot New Products Air Temperature And Humidity S...

      Measurement range 0~45m/s  0~70m/s Accuracy ±(0.3+0.03V)m/s (V: wind speed) Resolution 0.1m/s Staring wind speed ≤0.5m/s Power supply mode DC 5V  DC 12V  DC 24V  Other Out-put Current: 4~20mA  Voltage: 0~2.5V  Pulse:Pulse signal Voltage: 0~5V     RS232 RS485 TTL Level: (frequency; Pulse width) Other Instrument Line length Standard: 2.5m Other   Load capacity Current mode impedance≤600Ω Voltage mode impedance≥1KΩ Operating environment Temperat...

    • Manufacturer for Automatic Rain Gauge - Microcomputer automatic calorimeter – Huacheng

      Manufacturer for Automatic Rain Gauge - Microc...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...

    • Factory Supply Rain Thermometer - Microcomputer automatic calorimeter – Huacheng

      Factory Supply Rain Thermometer - Microcompute...

      Microcomputer automatic calorimeter is suitable for electric power, coal, metallurgy, petrochemical, environmental protection, cement, papermaking, ground can, scientific research institutions and other industrial sectors to measure the calorific value of coal, coke and petroleum and other combustible materials. In line with GB/T213-2008 “Coal thermal determination Method” GB/T384 “Determination of calorific value of petroleum products” JC/T1005-2006 “Cement blac...