Technique Parameter

Measurement range 0~45m/s 
0~70m/s
Accuracy ±(0.3+0.03V)m/s (V: wind speed)
Resolution 0.1m/s
Staring wind speed ≤0.5m/s
Power supply mode DC 5V 
DC 12V 
DC 24V 
Other
Out-put Current: 4~20mA 
Voltage: 0~2.5V 
Pulse:Pulse signal
Voltage: 0~5V    
RS232
RS485
TTL Level: (frequency; Pulse width)
Other
Instrument Line length Standard: 2.5m
Other  
Load capacity Current mode impedance≤600Ω
Voltage mode impedance≥1KΩ
Operating environment Temperature: -40℃~50℃
Humidity: ≤100%RH    
Defend grade IP45
Cable grade Nominal voltage:300V 
Temperature grade:80℃
Produce weight 130 g
Power dissipation 50 mW

Calculation Formula

Impulsive:
W =0; (f = 0)
W =0.3+0.0877×f(f≠ 0)
(W: indicating value of wind speed(m/s); f: pulse signal frequency)
Current mode (4~20mA):
W = (i-4)×45/16
(W: indicating value of wind speed (m/s); i: current type(4-20mA))
Voltage type(0~5V):
W =V/5×45
(W: indicating value of wind speed(m/s) ; V: voltage signal(0-5V))
Voltage type(0~2.5V):
W =V/2.5×45
(W: indicating value of wind speed(m/s); V: voltage signal (0-2.5V)

Wiring Method          

There is five-core aviation plug, whose output is at the base of the sensor. The definition of each pin’s corresponding base pin.

lf-001

1. If you have equipped with our company's weather station, please attach the sensor cable to the appropriate connector on the weather station directly.

2. If you purchase the sensor separately, the order of the wires are as followed:
R(Red): power +
Y(Yellow): signal output
G(Green): power —

3. Two ways of wiring method of pulse voltage and current:

wiring method of voltage and current

wiring method of voltage and current

output of current wiring method

output of current wiring method

Structure Dimensions

Structure Dimensions
Wind speed Sensor

Base mounting dimensions

Base mounting dimensions
Dimensional drawing of base installation:
Installation aperture: 4mm
Distribution Diameter: 62.5mm
Interface Dimension: 15mm (suggest reserving 25mm for wiring)

Transmitter Size

Transmitter Size   

RS485 (with address) communication protocol 

1. Serial format
8 data bits
1 stop bit
Parity None
Baud rate 9600,Two communication interval of at least 1000ms
2. The communication format
[1] Is written to the device address
Send: 00 10 00 AA (16 hexadecimal data)
Description: 00 - broadcast address (must be 0); 10 - Write operation (fixed); 00 - Address command (fixed); AA - write the new address (only,1-255)
Returns: OK (OK return success)
[2] To read the device address
Sent: 00 03 00 (hexadecimal data)
Description: 00 - broadcast address (must be 0); 03 - Read operation (fixed); 00 - Address command (fixed)
Returns: Address = XXX (ASCII code data, such as Address = 001, Address = 123, etc.)
Description: Address - address instructions; XXX - address data, less than three integer preceded 0
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and '=' character.
[3] Read real-time data
Send: AA 03 0F (16 decimal data)
Description: AA - Device address (only 1-255); 03 - read operation (fixed); 0F - data address (fixed)
Back: WS = XX.Xm/s (ASCII code data, such as WS =12.3m/s, WS = 00.5m/s)
Description: WS – Wind speed; XX.X – wind speed data, bring a decimal less than two integers, the leading zeros  m/s - units
[1] Which units followed with a carriage return wrap data, two-byte hexadecimal data 0x0D 0x0A;
[2] The above description ignores transition spaces and '=' character.

LF-0001 Wind Speed Sensor01

Precautions 

1. Please examine whether the package is intact or not please, and check whether the product is consistent with your selected type.
2. Be sure no power is applied before you ensure the wiring connection is errorless.
3. No alteration to factory-set components or cables.
4. Sensor is an accurate instrument. Do not separate, damage the interface of the sensor with sharp solid and corrosive liquid.
5. Please save the verification certification and Certificate of approval which may return to repair with the products.

Troubleshooting      

1. If anemometer bearing is not rotating well or have a big delay. It may because the long-term use lead to foreign matters in the bearings or weather there is any remained lubricating oil. Please inject the oil from the upside of bearings or post the sensors to our company to oiling.
2. If the indicated value is 0 or out of range when use analog output. It may be cause by cable connections. Please check weather the cable connections are correct and fastness.
3. If not the above reasons, please contact with us.

Selection Table

No Power supply Output Signal Instructions
LF-0001     wind speed sensors (transmitters)
  5V-   5Vpower supply
12V-   12Vpower supply
24V-   24Vpower supply
YV-   Other power supply
  V 0-5V
V1 1-5V
V2 0-2.5V
A1 4-20mA
A2 0-20mA
W1 RS232
W2 RS485
TL TTL
M pulse
X other
E.g. LF-0001-5V-M: wind speed sensorstransmitters5Vpower supply, output of pulse

Appendix: Wind force (wind velocity) Scale

Scale Description Land conditions Wind speed m/s
0 Calm Calm. Smoke rises vertically. 00.2
1 Light air Smoke drift indicates wind direction, still wind vanes. 0315
2 Light breeze Wind felt on exposed skin. Leaves rustle, vanes begin to move. 1633
3 Gentle breeze Leaves and small twigs constantly moving, light flags extended. 3454
4 Moderate Dust and loose paper raised. Small branches begin to move. 5579
5 Fresh breeze Branches of a moderate size move. Small trees in leaf begin to sway. 80107
6 Strong breeze Large branches in motion. Whistling heard in overhead wires. Umbrella use becomes difficult. Empty plastic garbage cans tip over. 10813.8
7 Moderate gale Whole trees in motion. Effort needed to walk against the wind. 13917l
8 Gale Some twigs broken from trees. Cars veer on road. Progress on foot is seriously impeded. 172207
9 Strong gale Some branches break off trees, and some small trees blow over. Construction/temporary signs and barricades blow over. 208244
10 Storm Trees are broken off or uprooted, saplings bent and deformed. Poorly attached asphalt shingles and shingles in poor condition peel off roofs. 245284
11 Violent storm Widespread damage to vegetation. Many roofing surfaces are damaged; asphalt tiles that have curled up and/or fractured due to age may break away completely. 285326
12 Hurricane-force Very widespread damage to vegetation. Some windows may break; mobile homes and poorly constructed sheds and barns are damaged. Debris may be hurled about. >32.6

  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • Wind Direction Sensor Weather Instrument

      Wind Direction Sensor Weather Instrument

      Technique Parameter  Measurement range:0~360° Accuracy:±3° Staring wind speed:≤0.5m/s Power supply mode:□ DC 5V □ DC 12V □ DC 24V □ Other Out-put:  □ Pulse:Pulse signal □ Current:4~20mA □ Voltage:0~5V □ RS232 □ RS485 □ TTL Level: (□frequency □Pulse width) □ Other Instrument line length:□ Standard:2.5m □ Other Load capacity:Current mode impedance≤300Ω Voltage mode impedance ≥1KΩ Operati...

    • LF-0012 handheld weather station

      LF-0012 handheld weather station

      Product introduction LF-0012 handheld weather station is a portable meteorological observation instrument that is convenient to carry, easy to operate, and integrates many meteorological elements. The system uses precision sensors and smart chips to accurately measure the five meteorological elements of wind speed, wind direction, atmospheric pressure, temperature, and humidity. The built-in large-cap...

    • Fixed single gas transmitter LCD display (4-20mA\RS485)

      Fixed single gas transmitter LCD display (4-20m...

      System Description System configuration Table 1 bill of materials for standard configuration of fixed single gas transmitter Standard configuration Serial number Name Remarks 1 Gas transmitter   2 Instruction manual   3 Certificate   4 Remote control   Please check whether the accessories and materials are complete after unpacking. Standard configuration is a ne...

    • Three Temperature and Three Humidity Soil Moisture Recorder

      Three Temperature and Three Humidity Soil Moist...

      Soil Moisture Sensor 1. Introduction The soil moisture sensor is a high-precision, high-sensitivity sensor that measures soil temperature. Its working principle is that measuring soil moisture through FDR (frequency domain method) can correspond to soil volumetric moisture content, which is a soil moisture measurement method that conforms to current international standards. The transmitter has signal acquisition, zero drift an...

    • Integrated wind speed and direction sensor

      Integrated wind speed and direction sensor

      Introduction The integrated wind speed and direction sensor is composed of wind speed sensor and wind direction sensor. The wind speed sensor adopts the traditional three-cup wind speed sensor structure, and the wind cup is made of carbon fiber material with high strength and good start-up; the signal processing unit embedded in the cup can output the corresponding wind speed signal according to the ...

    • Rain sensor stainless steel outdoor hydrological station

      Rain sensor stainless steel outdoor hydrologica...

      Technique Parameter Water-carrying caliber Ф200 ± 0.6mm Measuring range ≤4mm / min (precipitation intensity) Resolution 0.2mm (6.28ml) Accuracy ± 4% (indoor static test, rain intensity is 2mm / min) Power supply mode DC 5V  DC 12V  DC 24V  Other Output form Current 4 ~ 20mA Switching signal: On-off of reed switch Voltage: 0~2.5V  Voltage: 0~5V     Voltage 1 ~ 5V Other ...